91天堂国产在线-а√在线中文在线新版-国产成人精品一区二区三区在线-国产午夜精品久久久久久免费视-精品国产乱码久久久久久牛牛-久久久裸体视频

現代資訊現代實驗室裝備網
全國服務熱線
400-100-9187、0731-84444840

Alkylphenol(AP) ELISA Kit烷基酚

 
品牌: 1048
單價: 面議
起訂:
供貨總量:
發貨期限: 自買家付款之日起 天內發貨
所在地: 全國
有效期至: 長期有效
最后更新: 1970-01-01 08:00
瀏覽次數: 180
 
公司基本資料信息
詳細說明
Alkylphenol(AP) ELISA Kit烷基酚
 
AP ELISA Kit
• The monoclonal antibody binds exclusively with Alkylphenol(AP) , and does not cross-react with other surfactants or compounds of similar structure. 
• The detection range is between 5μg/L and 500μg/L. A simple concentration protocol based on solid phase extraction is available to determine much lower concentration. 
• With ease of handling, the total time for measurement is only 2.5 hours. 
• The kit, a 96-well microplate format, enables simultaneous measurement of multiple samples at more reasonable cost.
AP
AP is suspected as one of the endocrine disrupting chemicals in many countries. 
Octylphenol (n=8) and nonylphenol (n=9) are widely used as raw material of surfactants and anti-oxidants.
AP is generated by microbial decomposition of ethylene oxide chains in APE, which is widely used as nonionic surfactant. 
NPnEC, another decomposed product of APE, is also assumed as hormone mimicking chemicals.

AP Standard Curve 
 
 Samples containing AP within the dynamic range (5μg/L- 500μg/L) can be directly applied to assay after filtration. Samples with AP content below the range must be concentrated with solid phase extraction prior to the ensuing session. 
Coefficient of variation(CV) is generally under 10% throughout the dynamic range.


Pretreatment (Simplified Solid Phase Extraction) 
If an extraction and a concentration process is not necessary, add methanol to the filtrate to be a final DMSO concentration of 1% and methanol concentration of 10% (v/v). If not, prepare each sample by the extraction procedure.

[Example] 

1. Rinse a NEXUS SPE solid phase cartridge at 20ml/min. with dichloromethan (10mL) and methanol (5mL) then with distilled water (5mL). 
2. Pour sample liquid through the cartridge at 10mL/min. (up to about 1L) 
3. Wash the cartridge with distilled water (5mL). 
4. Wash the cartridge with 50% methanol (5mL). 
5. Dry the cartridge with vacuuming. 
6. Elute the analyte with dochloromethane (6mL) then evaporate the solvent with nitrogen gas. 
7. Dissolve the residue in 1%DMSO,10%methanol (1 to 2mL). 
8. Measure the sample with AP ELISA kit. 
Cross-reactivity Pattern 

Compound % reactivity
Nonylphenol (NP) 100
Octylphenol (OP) 96
Nonylphenol Ethoxylate (NPnEO)
NPnEO (n=1) 1.2
NPnEO (n=2) 2.1
NPnEO (n≒5) 3.2
NPnEO (n≒7.5) 4.5
NPnEO (n≒10) 4.9
Octylphenol Ethoxylate (OPnEO)
OPnEO (n≒10) 2.8
Nonylphenol Ethoxy Acetic acid (NPnEC)
NPnEC (n=1) 0.5
NPnEC (n=2) 1.5
NPnEC (n=3) 3.8
Anionic Surfactants
Linear Alkylbenzene Sulfonates (LAS) <0.1
Sodium Dodecyl Sulfate (SDS) <0.1
Alkylether Sulfate (AES) <0.1
Sodium Laurate (SORP) <0.1

Kit Format 
Kit Format Content Comment
Microplate 96 wells
& reagents Needs a microplate reader(450nm)
For multiple and simultaneous measurement

如有更多其它試劑產品需求與查詢,請及時接洽:info@express-cn.com 或在我公司查詢主頁客戶留言處(http://www.express-cn.com/expressgb/lyb.htm )留下您的查詢內容,我們即會在當天為您作出回復。

伊普瑞斯科技有限公司
info@express-cn.com  
在線客服:QQ:1069267096
         MSN:liyuqiu1983@hotmail.com 
               cindylee-1981@hotmail.com 
聯系人:楊先生
總機:010-60206266
傳真:010-60206773
www.express-cn.com 

反對 0舉報 0 收藏 0 評論 0
更多>本企業其它產品
?